FLOW RANGES 0.5 – 15 GPM (gal/min) 1.5 – 50 GPM PRESSURE Working pressure up to 500 psi (up to 200 psi w/ optional clear cover) ACCURACY ± 2% of full scale or better
{loadposition sureflow-01header}
SERIES TT : STANDARD PADDLE WHEEL SENSOR
FEATURES/BENEFITS:
- FLOW RANGES
0.5 – 15 GPM (gal/min) 1.5 – 50 GPM - PRESSURE
Working pressure up to 500 psi (up to 200 psi w/ optional clear cover) - ACCURACY
± 2% of full scale or better - REPEATABILITY
± 0.5% of full scale or better Reads in GPM and LPM scale - LINEAR TURN DOWN RATIO
10:1 - TEMPERATURE
Fluid temperature of 20° to 225°F - FILTRATION
150 microns - END CONNECTIONS
NPT(F)
GENERAL DESCRIPTION:
Benefits:
CHOICE OF THREE PORT SIZES
Select from 1/2” , 3/4” or 1” NPT(F) porting to meet system requirements.
EASY MAINTENANCE AND CLEANING
Has only one moving component, the impeller. Cleaning and maintenance may be performed without removing the sensor from the piping.
SEVERAL OUTPUTS AVAILABLE
The standard interface is a 2-wire, 4-20mA current loop. Sensor signal may be transmitted on a low cost wire without degradation. Pulse and 0-5 VDC are also available.
HERMETICALLY ENCAPSULATED CIRCUITRY Withstands the harshest environments.
CONNECTS DIRECTLY TO YOUR FLOW MONITORING INSTRUMENTS
Can be connected directly to analog acquisition cards, chart recorders or other monitoring instruments, without external signal conditioning.
SIMPLY PLUMB AND APPLY POWER
Comes factory calibrated to your fl ow range specifi cations. VALUE PRICING Combined with low cost operation and maintenance, equals better bottom line savings for your operation.
ELECTRICAL DATA
4-20 mA Version: | |
Power requirements: | 12 – 35 VDC, loop powered |
Load driving capacity | 1150 Ohms maximum |
Maximum transmitting distance | Limited only by wire resistance & supply voltage |
Response time | 2 seconds to 90% (step change) |
Resolution | Infinite |
Over-current limit | Self limiting at 35 mA |
Other protection | Reverse polarity |
0-5 VDC Version: | |
Power requirements | 12 – 35 VDC |
Maximum current | 25 mA DC |
Minimum load resistance | 1000 Ohms |
Maximum transmission distance | 200 feet recommended |
Response time | > 5 seconds to 90% (step change) |
Resolution | Infinite |
Pulse Output Version: | |
Power requirements | 5 – 24 VDC |
Maximum current | 25 mA DC |
Minimum load resistance | 1000 Ohms |
Maximum transmission distance | 200 feet recommended |
Response time | 100 mS |
Protection | Short circuit & reverse polarity |
K-Factor | 1/2″ port = 200 pulses/gallon 3/4′ & 1″ ports = 60 pulses/gallon |
Relay Output Version: | |
Power requirement | 12 – 35 VDC |
Maximum transmission distance | 200 feet recommended |
Switch contact | Form C, 5A max @ 120 or 240 VAC |
Hysteresis | 5% of set point maximum |
Set point repeatability | 1% of full scale |
METER DIMENSIONS
DIM | 1/2″ NPTF | 3/4″ – 1″ NPTF |
A | 1.94″ {49mm} | 3.06″ {78mm} |
B | 1.13″ {29mm} | 1.33″ {34mm} |
C | 2.00″ {51mm} | 2.46″ {62mm} |
D | 2.60″ {66mm} | 2.88″ {73mm} |
E | 3.70″ {94mm} | 5.25″ {133mm} |
F | 2.63″ {67mm} | 3.80″ {97mm} |