In accordance with the CE requirements of EMC Directive 89/336/EEC, ROHS Directive 2002/95/EY
{loadposition fd-01header}
Model A2G-25 Air Flow Meter Type A2G-25
Overview
Version
In accordance with the CE requirements of EMC Directive 89/336/EEC, ROHS Directive 2002/95/EY
Accuracy
At 4 InWC and 8 InWC ± 0.02 InWC: ±1.5 % of display
At 20 InWC and 28 InWC : ±0.03 InWC: ±1.5 % of display
Display ranges
0 … 4 InWC, 0 … 8 InWC, 0 … 20 InWC or 0 … 28 InWC
Selectable units on the display: LPM, m3/s, m3/h, cfm, l/s, scfh, mbar, mmWC, kPa or Pa
Long-term stability
At 4 InWC and 8 InWC: ±0.03 InWC
At 20 InWC and 28 InWC: ±0.1 InWC
Manual zero adjustment (standard)
Automatic zero adjustment (optional): ±0.03 InWC
Maximum working pressure
100 InWC
Operating temperature
Ambient: -4…+160°F
Medium: 23 … +122 °F
Permissible ambient humidity
0 … 95 % rH, non-condensing
Ingress protection
NEMA 3 (IP54 per EN 60529 / IEC 529)
Weight
5.2 ounces (150 grams )
Features
- Easy installation
- User-friendly display
- Easy-to-read LCD display
- Temperature compensated
- Output signals for differential pressure and air volume flow